Clear Across Kansas

Minneapolis 2 11/18/2017

Repeater, 7330, and MMDVM integration.

Date of PM: 11/18/2017
S-Com 7330
Raytheon SNV-12
MMDVM

Repeater – Harris Mastr III – 110 watts
Power output: 90 watts
Primary RX Sensitivity: .20 uV
Freq error: within 100 Hz
Local RX Sensitivity: .20 uV
Freq error: within 100 Hz
Transmitter maximum deviation: +- 5000 Hz
Channel Guard deviation: +-650 Hz (162.2) – +-700 Hz (123.0)
System Fusion deviation: +- 4750 Hz
DMR deviation: +- 2750 Hz
Repeat audio: 1:1 up to +-4.6 kHz (including CG).

All voter RX sensitivity measurements are performed through the RX Multicoupler.
Voter RX #1
RX Sensitivity: .22 uV
Freq error: within 100 Hz

Voter RX #2
RX Sensitivity: .22 uV
Freq error: within 100 Hz

Voter RX #3
RX Sensitivity: .22 uV
Freq error: within 100 Hz

Lincoln Remote RX
RX Sensitivity: .20 uV
Freq error: within 100 Hz
Link TX power: 8 watts

Salina Remote RX
RX Sensitivity: .22 uV
Freq error: within 100 Hz
Link TX power: 6 watts

RX audio at TP: .360 VRMS @ 3 kHz/1 kHz tone
IRLP audio output: audiotest 1 kHz tone set to 3.65 kHz deviation (including CG).
IRLP audio input: adjusted for 1:1 match on echo reflector.

Allstar audio output: Echo mode, 1kHz tone at 3 kHz deviation produces 3 kHz devation + PL tone.
Allstar audio input: 1 kHz tone at 3 kHz deviation shows 3 kHz on the VU meter.

Next PM due: 5/18/2019